On-grid rooftop system, designed step by step
The same sizing a designer checks before modelling the system in PVsyst and drawing it in AutoCAD.
Best for: Homes, schools, and offices with a reliable grid connection that want to cut their electricity bill.
Components
- Solar PV panels (e.g. 545 Wp mono PERC / TOPCon)
- Grid-tie string inverter
- DC distribution box (DCDB) with SPD and fuses
- AC distribution box (ACDB) with MCB and SPD
- Bi-directional net meter (from the electricity board)
- Mounting structure, earthing, and a lightning arrester
Sizing, step by step
A home using about 300 kWh a month (10 kWh a day), in a location with about 4.5 peak sun hours a day.
- 1Daily energy need: 300 kWh ÷ 30 days = 10 kWh/day
- 2PV array size: 10 kWh ÷ (4.5 sun hours × 0.8 performance ratio) ≈ 2.8 kWp → round up to 3 kWp
- 3Number of panels: 3,000 W ÷ 545 W ≈ 5.5 → 6 panels = 3.27 kWp
- 4Inverter: Match the array: a 3 kW grid-tie inverter (DC:AC ratio ≈ 1.1)
- 5Roof area: About 7 m² per kWp → roughly 22–25 m² of shade-free roof
- 6Expected generation: 3.27 kWp × 4.5 h × 0.8 × 30 days ≈ 350 kWh/month — confirm with a PVsyst simulation
Final design
- • 6 × 545 Wp panels (3.27 kWp), one string
- • 3 kW single-phase grid-tie inverter
- • Net meter, DCDB, ACDB, earthing, lightning arrester
- • ≈ 350 kWh/month — covers the full monthly bill
Advantages
- + Lowest cost per unit — no battery to buy or replace
- + Surplus units are credited through net metering
- + Almost no maintenance beyond cleaning panels
- + Eligible for government rooftop subsidies (check the current PM Surya Ghar scheme)
Watch out for
- ! Shuts down during a power cut (anti-islanding safety) — no backup power
- ! Needs electricity-board approval and a net meter before switch-on
- ! Shading on even one panel can cut the whole string's output — check it in the 3D model first